webshop.nl
Categorieën
  Sluiten

Meer Schneider Electric
Meer Schneider Electric in Klussen

GV2L10 - Motor protection circuit-breaker 6,3A GV2L10

EAN: 3389110213263 - manufacturer-number: GV2L10 - Overload release current setting=6,3 A, Adjustment range undelayed short-circuit release=78 A, With thermal protection=no, Phase failure sensitive=yes, Switch off technique=Magnetic, Rated operating voltage=0..690 V, Rated permanent current Iu=6,3 A, Rated operation power at AC-3, 230 V=1,5 kW, Rat...
60,62

Webshops met dit product

Webshop
Bezorging
Prijs

Anderen bekeken ook

3RV2311-1GC10  - Motor protection circuit-breaker 6,3A 3RV2311-1GC10
3RV2311-1GC10 - Motor protection circuit-breaker 6,3A 3RV2311-1GC10
EAN: 4011209714441 - manufacturer-number: 3RV2311-1GC10 - Adjustment range undelayed short-circuit release = 82 A, With thermal protection = no, Phase failure sensitive = no, Switch off technique = Magnetic, Rated operating voltage = 690 V, Rated permanent current Iu = 6,3 A, Rated operation power at AC-3, 230 V = 1,5 kW, Rated operation power at AC-3, 400 V = 2,2 kW, Type of electrical connection of main circuit = Screw connection, Type of control element = Turn button, Device construction = Built-in device fixed built-in technique, With integrated auxiliary switch = no, With integrated under voltage release = no, Number of poles = 3, Rated short-circuit breaking capacity lcu at 400 V, AC = 100 kA, Degree of protection (IP) = IP20, Height = 97 mm, Width = 45 mm, Depth = 97 mm - 3RV2311-1GC10
62,02
GV2P10  - Motor protection circuit-breaker GV2P10
GV2P10 - Motor protection circuit-breaker GV2P10
EAN: 3389110213485 - manufacturer-number: GV2P10 - Overload release current setting=4..6,3 A, Adjustment range undelayed short-circuit release=78 A, With thermal protection=yes, Phase failure sensitive=yes, Switch off technique=Thermomagnetic, Rated operating voltage=0..690 V, Rated permanent current Iu=6,29999999 A, Rated operation power at AC-3, 230 V=1,5 kW, Rated operation power at AC-3, 400 V=2,2 kW, Type of electrical connection of main circuit=Screw connection, Type of control element=Turn button, Device construction=Complete device in housing, With integrated auxiliary switch=no, With integrated under voltage release=no, Number of poles=3, Rated short-circuit breaking capacity lcu at 400 V, AC=100 kA, Degree of protection (IP)=IP20, Height=89 mm, Width=45 mm, Depth=97 mm - GV2P10
64,26
GV2L08  - Motor protection circuit-breaker 4A GV2L08
GV2L08 - Motor protection circuit-breaker 4A GV2L08
EAN: 3389110213256 - manufacturer-number: GV2L08 - Overload release current setting=4 A, Adjustment range undelayed short-circuit release=51 A, With thermal protection=no, Phase failure sensitive=yes, Switch off technique=Magnetic, Rated operating voltage=0..690 V, Rated permanent current Iu=4 A, Rated operation power at AC-3, 230 V=0,75 kW, Rated operation power at AC-3, 400 V=1,5 kW, Type of electrical connection of main circuit=Screw connection, Type of control element=Turn button, Device construction=Complete device in housing, With integrated auxiliary switch=no, With integrated under voltage release=no, Number of poles=3, Rated short-circuit breaking capacity lcu at 400 V, AC=100 kA, Degree of protection (IP)=IP20, Height=89 mm, Width=45 mm, Depth=97 mm - GV2L08
60,62
GV2P04  - Motor protection circuit-breaker 0,63A GV2P04
GV2P04 - Motor protection circuit-breaker 0,63A GV2P04
EAN: 3389110213430 - manufacturer-number: GV2P04 - Overload release current setting=0,4..0,63 A, Adjustment range undelayed short-circuit release=8 A, With thermal protection=yes, Phase failure sensitive=yes, Switch off technique=Thermomagnetic, Rated operating voltage=0..690 V, Rated permanent current Iu=0,63 A, Rated operation power at AC-3, 230 V=0,09 kW, Rated operation power at AC-3, 400 V=0,18 kW, Type of electrical connection of main circuit=Screw connection, Type of control element=Turn button, Device construction=Complete device in housing, With integrated auxiliary switch=no, With integrated under voltage release=no, Number of poles=3, Rated short-circuit breaking capacity lcu at 400 V, AC=100 kA, Degree of protection (IP)=IP20, Height=89 mm, Width=45 mm, Depth=97 mm - GV2P04
58,17
GV2P05  - Motor protection circuit-breaker 1A GV2P05
GV2P05 - Motor protection circuit-breaker 1A GV2P05
EAN: 3389110213447 - manufacturer-number: GV2P05 - Overload release current setting=0,63..1 A, Adjustment range undelayed short-circuit release=13 A, With thermal protection=yes, Phase failure sensitive=yes, Switch off technique=Thermomagnetic, Rated operating voltage=0..690 V, Rated permanent current Iu=1 A, Rated operation power at AC-3, 230 V=0,18 kW, Rated operation power at AC-3, 400 V=0,37 kW, Type of electrical connection of main circuit=Screw connection, Type of control element=Turn button, Device construction=Complete device in housing, With integrated auxiliary switch=no, With integrated under voltage release=no, Number of poles=3, Rated short-circuit breaking capacity lcu at 400 V, AC=100 kA, Degree of protection (IP)=IP20, Height=89 mm, Width=45 mm, Depth=97 mm - GV2P05
63,38
GV2P32  - Motor protection circuit-breaker 32A GV2P32
GV2P32 - Motor protection circuit-breaker 32A GV2P32
EAN: 3389110376104 - manufacturer-number: GV2P32 - Overload release current setting=24..32 A, Adjustment range undelayed short-circuit release=416 A, With thermal protection=yes, Phase failure sensitive=yes, Switch off technique=Thermomagnetic, Rated operating voltage=0..690 V, Rated permanent current Iu=32 A, Rated operation power at AC-3, 230 V=7,5 kW, Rated operation power at AC-3, 400 V=15 kW, Type of electrical connection of main circuit=Screw connection, Type of control element=Turn button, Device construction=Complete device in housing, With integrated auxiliary switch=no, With integrated under voltage release=no, Number of poles=3, Rated short-circuit breaking capacity lcu at 400 V, AC=50 kA, Degree of protection (IP)=IP20, Height=89 mm, Width=45 mm, Depth=97 mm - GV2P32
134,93
GV2P21  - Motor protection circuit-breaker 23A GV2P21
GV2P21 - Motor protection circuit-breaker 23A GV2P21
EAN: 3389110213522 - manufacturer-number: GV2P21 - Overload release current setting=17..23 A, Adjustment range undelayed short-circuit release=327 A, With thermal protection=yes, Phase failure sensitive=yes, Switch off technique=Thermomagnetic, Rated operating voltage=0..690 V, Rated permanent current Iu=23 A, Rated operation power at AC-3, 230 V=5,5 kW, Rated operation power at AC-3, 400 V=9 kW, Type of electrical connection of main circuit=Screw connection, Type of control element=Turn button, Device construction=Complete device in housing, With integrated auxiliary switch=no, With integrated under voltage release=no, Number of poles=3, Rated short-circuit breaking capacity lcu at 400 V, AC=50 kA, Degree of protection (IP)=IP20, Height=89 mm, Width=45 mm, Depth=97 mm - GV2P21
92,67
GV2RT08  - Motor protection circuit-breaker 4A GV2RT08
GV2RT08 - Motor protection circuit-breaker 4A GV2RT08
EAN: 3389110520644 - manufacturer-number: GV2RT08 - Overload release current setting=2,5..4 A, Adjustment range undelayed short-circuit release=78 A, With thermal protection=yes, Phase failure sensitive=yes, Switch off technique=Thermomagnetic, Rated operating voltage=0..690 V, Rated permanent current Iu=4 A, Rated operation power at AC-3, 230 V=0,75 kW, Rated operation power at AC-3, 400 V=1,5 kW, Type of electrical connection of main circuit=Screw connection, Type of control element=Rocker lever, Device construction=Complete device in housing, With integrated auxiliary switch=no, With integrated under voltage release=no, Number of poles=3, Rated short-circuit breaking capacity lcu at 400 V, AC=100 kA, Degree of protection (IP)=IP20, Height=89 mm, Width=45 mm, Depth=78,5 mm - GV2RT08
61,27
GV2P07  - Motor protection circuit-breaker 2,5A GV2P07
GV2P07 - Motor protection circuit-breaker 2,5A GV2P07
EAN: 3389110213461 - manufacturer-number: GV2P07 - Overload release current setting=1,6..2,5 A, Adjustment range undelayed short-circuit release=33,5 A, With thermal protection=yes, Phase failure sensitive=yes, Switch off technique=Thermomagnetic, Rated operating voltage=0..690 V, Rated permanent current Iu=2,5 A, Rated operation power at AC-3, 230 V=0,37 kW, Rated operation power at AC-3, 400 V=0,75 kW, Type of electrical connection of main circuit=Screw connection, Type of control element=Turn button, Device construction=Complete device in housing, With integrated auxiliary switch=no, With integrated under voltage release=no, Number of poles=3, Rated short-circuit breaking capacity lcu at 400 V, AC=100 kA, Degree of protection (IP)=IP20, Height=89 mm, Width=45 mm, Depth=97 mm - GV2P07
64,26
GV2P16  - Motor protection circuit-breaker 14A GV2P16
GV2P16 - Motor protection circuit-breaker 14A GV2P16
EAN: 3389110213508 - manufacturer-number: GV2P16 - Overload release current setting=9..14 A, Adjustment range undelayed short-circuit release=170 A, With thermal protection=yes, Phase failure sensitive=yes, Switch off technique=Thermomagnetic, Rated operating voltage=0..690 V, Rated permanent current Iu=14 A, Rated operation power at AC-3, 230 V=3 kW, Rated operation power at AC-3, 400 V=5,5 kW, Type of electrical connection of main circuit=Screw connection, Type of control element=Turn button, Device construction=Complete device in housing, With integrated auxiliary switch=no, With integrated under voltage release=no, Number of poles=3, Rated short-circuit breaking capacity lcu at 400 V, AC=100 kA, Degree of protection (IP)=IP20, Height=89 mm, Width=45 mm, Depth=97 mm - GV2P16
76,77

Klanten-reviews van GV2L10 - Motor protection circuit-breaker 6,3A GV2L10

Er zijn nog geen beoordelingen voor dit productBen jij de eerste die een review plaatst?

Meer over GV2L10 - Motor protection circuit-breaker 6,3A GV2L10

Productomschrijving

EAN: 3389110213263 - manufacturer-number: GV2L10 - Overload release current setting=6,3 A, Adjustment range undelayed short-circuit release=78 A, With thermal protection=no, Phase failure sensitive=yes, Switch off technique=Magnetic, Rated operating voltage=0..690 V, Rated permanent current Iu=6,3 A, Rated operation power at AC-3, 230 V=1,5 kW, Rated operation power at AC-3, 400 V=2,2 kW, Type of electrical connection of main circuit=Screw connection, Type of control element=Turn button, Device construction=Complete device in housing, With integrated auxiliary switch=no, With integrated under voltage release=no, Number of poles=3, Rated short-circuit breaking capacity lcu at 400 V, AC=100 kA, Degree of protection (IP)=IP20, Height=89 mm, Width=45 mm, Depth=97 mm - GV2L10

Productspecificaties

Artikelnummer(s)
EAN
3389110213263
Brand
Schneider Electric
Webshop.nl maakt gebruik van cookies. Ga je verder op onze website, ga dan akkoord met het plaatsen van cookies en de verwerking van deze data door ons en vermelde partners.