DAFDD 1 C16/0,03/2-A - Earth leakage circuit breaker with DAFDD 1 C16/0,03/2-A

EAN: 4014712235922 - manufacturer-number: DAFDD1C16/0,03/2-A - Earth leakage circuit breaker with Number of poles 2, Rated voltage 240V, Rated current 16A, Rated fault current 0,03A, Leakage current type A, Current limiting class 3, Rated short-circuit breaking capacity acc. EN 61009 10kA, Frequency 50Hz, Release characteristic C, Over voltage cate...
161,72

Webshops met dit product

Webshop
Bezorging
Prijs

Anderen bekeken ook

DAFDD 1 B16/0,03/2-A  - Earth leakage circuit breaker with DAFDD 1 B16/0,03/2-A
DAFDD 1 B16/0,03/2-A - Earth leakage circuit breaker with DAFDD 1 B16/0,03/2-A
EAN: 4014712235809 - manufacturer-number: DAFDD1B16/0,03/2-A - Earth leakage circuit breaker with Number of poles 2, Rated voltage 240V, Rated current 16A, Rated fault current 0,03A, Leakage current type A, Current limiting class 3, Rated short-circuit breaking capacity acc. EN 61009 10kA, Frequency 50Hz, Release characteristic B, Over voltage category 3, Pollution degree 2, Width in number of modular spacings 3, Built-in depth 70mm, Additional equipment attached at delivery Fire protection switch, Rated switch current auxiliary device 16A, Rated voltage auxiliary device 240V, Control voltage type auxiliary equipment AC, Degree of protection (IP) IP20 - DAFDD 1 B16/0,03/2-A
126,83
DAFDD1C16/0,03/2-AKV  - Earth leakage circuit breaker with DAFDD1C16/0,03/2-AKV
DAFDD1C16/0,03/2-AKV - Earth leakage circuit breaker with DAFDD1C16/0,03/2-AKV
EAN: 4014712235946 - manufacturer-number: DAFDD1C16/0,03/2-AKV - Earth leakage circuit breaker with Number of poles 2, Rated voltage 240V, Rated current 16A, Rated fault current 0,03A, Leakage current type A, Current limiting class 3, Rated short-circuit breaking capacity acc. EN 61009 10kA, Frequency 50Hz, Release characteristic C, Over voltage category 3, Pollution degree 2, Width in number of modular spacings 3, Built-in depth 70mm, Additional equipment attached at delivery Fire protection switch, Rated switch current auxiliary device 16A, Rated voltage auxiliary device 240V, Control voltage type auxiliary equipment AC, Degree of protection (IP) IP20 - DAFDD1C16/0,03/2-AKV
207,36
DAFDD 1 B10/0,03/2-A  - Earth leakage circuit breaker with DAFDD 1 B10/0,03/2-A
DAFDD 1 B10/0,03/2-A - Earth leakage circuit breaker with DAFDD 1 B10/0,03/2-A
EAN: 4014712235328 - manufacturer-number: DAFDD1B10/0,03/2-A - Earth leakage circuit breaker with Number of poles 2, Rated voltage 240V, Rated current 10A, Rated fault current 0,03A, Leakage current type A, Current limiting class 3, Rated short-circuit breaking capacity acc. EN 61009 10kA, Frequency 50Hz, Release characteristic B, Over voltage category 3, Pollution degree 2, Width in number of modular spacings 3, Built-in depth 70mm, Additional equipment attached at delivery Fire protection switch, Rated switch current auxiliary device 10A, Rated voltage auxiliary device 240V, Control voltage type auxiliary equipment AC, Degree of protection (IP) IP20 - DAFDD 1 B10/0,03/2-A
156,10
DAFDD 1 C40/0,03/2-A  - Earth leakage circuit breaker with DAFDD 1 C40/0,03/2-A
DAFDD 1 C40/0,03/2-A - Earth leakage circuit breaker with DAFDD 1 C40/0,03/2-A
EAN: 4014712236424 - manufacturer-number: DAFDD1C40/0,03/2-A - Earth leakage circuit breaker with Number of poles 2, Rated voltage 240V, Rated current 40A, Rated fault current 0,03A, Leakage current type A, Current limiting class 3, Rated short-circuit breaking capacity acc. EN 61009 6kA, Frequency 50Hz, Release characteristic C, Over voltage category 3, Pollution degree 2, Width in number of modular spacings 3, Built-in depth 70mm, Additional equipment attached at delivery Fire protection switch, Rated switch current auxiliary device 40A, Rated voltage auxiliary device 240V, Control voltage type auxiliary equipment AC, Degree of protection (IP) IP20 - DAFDD 1 C40/0,03/2-A
206,79
DAFDD 1 B40/0,03/2-A  - Earth leakage circuit breaker with DAFDD 1 B40/0,03/2-A
DAFDD 1 B40/0,03/2-A - Earth leakage circuit breaker with DAFDD 1 B40/0,03/2-A
EAN: 4014712236363 - manufacturer-number: DAFDD1B40/0,03/2-A - Earth leakage circuit breaker with Number of poles 2, Rated voltage 240V, Rated current 40A, Rated fault current 0,03A, Leakage current type A, Current limiting class 3, Rated short-circuit breaking capacity acc. EN 61009 6kA, Frequency 50Hz, Release characteristic B, Over voltage category 3, Pollution degree 2, Width in number of modular spacings 3, Built-in depth 70mm, Additional equipment attached at delivery Fire protection switch, Rated switch current auxiliary device 40A, Rated voltage auxiliary device 240V, Control voltage type auxiliary equipment AC, Degree of protection (IP) IP20 - DAFDD 1 B40/0,03/2-A
189,32
DRCBO3C16/0,03/1NAKV  - Earth leakage circuit breaker C16/0,03A DRCBO3C16/0,03/1NAKV
DRCBO3C16/0,03/1NAKV - Earth leakage circuit breaker C16/0,03A DRCBO3C16/0,03/1NAKV
EAN: 4014712221000 - manufacturer-number: DRCBO3C16/0,03/1NAKV - Earth leakage circuit breaker C16/0,03A Number of poles (total) 2, Number of protected poles 1, Rated voltage 230V, Rated insulation voltage Ui 440V, Rated impulse withstand voltage Uimp 4kV, Rated current 16A, Rated fault current 0,03A, Leakage current type A, Current limiting class 3, Rated short-circuit breaking capacity acc. EN 61009 10kA, Rated short-circuit breaking capacity IEC 60947-2 10kA, Rated short-circuit breaking capacity Icn acc. EN 61009-1 10kA, Disconnection characteristic Short-time delayed, Surge current capacity 3kA, Voltage type AC, Frequency 50 Hz, Release characteristic C, Over voltage category 3, Pollution degree 2, Ambient temperature during operating -25 ... 40°C, Width in number of modular spacings 2, Built-in depth 68mm, Degree of protection (IP) IP20, Connectable conductor cross section solid-core 1 ... 25mm², Connectable conductor cross section multi-wired 1 ... 25mm² - DRCBO3C16/0,03/1NAKV
94,52
DS201A-C16/0,03  - Earth leakage circuit breaker C16/0A DS201A-C16/0,03
DS201A-C16/0,03 - Earth leakage circuit breaker C16/0A DS201A-C16/0,03
EAN: 8012542739319 - manufacturer-number: DS201A-C16/0,03 - Earth leakage circuit breaker C16/0A Number of poles (total) 2, Number of protected poles 1, Rated voltage 230V, Rated current 16A, Rated fault current 0A, Leakage current type A, Rated short-circuit breaking capacity acc. EN 61009 6kA, Rated short-circuit breaking capacity IEC 60947-2 10kA, Surge current capacity 0kA, Voltage type AC, Frequency 50/60 Hz, Release characteristic C, Concurrently switching N-neutral, Over voltage category 3, Pollution degree 2, Ambient temperature during operating 55 ... 55°C, Width in number of modular spacings 2, Built-in depth 69mm, Degree of protection (IP) IP2X - DS201A-C16/0,03
58,29
DS201MA-C16/0,03  - Earth leakage circuit breaker C16/0A DS201MA-C16/0,03
DS201MA-C16/0,03 - Earth leakage circuit breaker C16/0A DS201MA-C16/0,03
EAN: 8012542592815 - manufacturer-number: DS201MA-C16/0,03 - Earth leakage circuit breaker C16/0A Number of poles (total) 2, Number of protected poles 1, Rated voltage 230V, Rated current 16A, Rated fault current 0A, Leakage current type A, Rated short-circuit breaking capacity acc. EN 61009 10kA, Rated short-circuit breaking capacity IEC 60947-2 15kA, Surge current capacity 0kA, Voltage type AC, Frequency 50/60 Hz, Release characteristic C, Concurrently switching N-neutral, Over voltage category 3, Pollution degree 2, Ambient temperature during operating 55 ... 55°C, Width in number of modular spacings 2, Built-in depth 69mm, Degree of protection (IP) IP2X - DS201MA-C16/0,03
101,70
DRCBO3 C16/0,03/1N-A  - Earth leakage circuit breaker C16/0,03A DRCBO3 C16/0,03/1N-A
DRCBO3 C16/0,03/1N-A - Earth leakage circuit breaker C16/0,03A DRCBO3 C16/0,03/1N-A
EAN: 4014712220744 - manufacturer-number: DRCBO3C16/0,03/1N-A - Earth leakage circuit breaker C16/0,03A Number of poles (total) 2, Number of protected poles 1, Rated voltage 230V, Rated insulation voltage Ui 440V, Rated impulse withstand voltage Uimp 4kV, Rated current 16A, Rated fault current 0,03A, Leakage current type A, Current limiting class 3, Rated short-circuit breaking capacity acc. EN 61009 10kA, Rated short-circuit breaking capacity Icn acc. EN 61009-1 10kA, Disconnection characteristic Undelayed, Surge current capacity 0,25kA, Voltage type AC, Frequency 50 Hz, Release characteristic C, Over voltage category 3, Pollution degree 2, Ambient temperature during operating -25 ... 40°C, Width in number of modular spacings 2, Built-in depth 68mm, Degree of protection (IP) IP20, Connectable conductor cross section solid-core 1 ... 25mm², Connectable conductor cross section multi-wired 1 ... 25mm² - DRCBO3 C16/0,03/1N-A
52,59
AFDD-16/2/B/001-A  - Earth leakage circuit breaker with AFDD-16/2/B/001-A
AFDD-16/2/B/001-A - Earth leakage circuit breaker with AFDD-16/2/B/001-A
EAN: 4015081822508 - manufacturer-number: AFDD-16/2/B/001-A - Earth leakage circuit breaker with Number of poles 2, Rated voltage 230V, Rated current 16A, Rated fault current 0,01A, Leakage current type A, Current limiting class 3, Rated short-circuit breaking capacity acc. EN 61009 10kA, Rated short-circuit breaking capacity IEC 60947-2 0kA, Frequency 50Hz, Release characteristic B, Over voltage category 3, Pollution degree 2, Width in number of modular spacings 3, Built-in depth 67mm, Additional equipment attached at delivery Fire protection switch, Rated switch current auxiliary device 0A, Rated voltage auxiliary device 230V, Control voltage type auxiliary equipment AC, Degree of protection (IP) IP20 - AFDD-16/2/B/001-A
170,61

Klanten-reviews van DAFDD 1 C16/0,03/2-A - Earth leakage circuit breaker with DAFDD 1 C16/0,03/2-A

Er zijn nog geen beoordelingen voor dit productBen jij de eerste die een review plaatst?

Meer over DAFDD 1 C16/0,03/2-A - Earth leakage circuit breaker with DAFDD 1 C16/0,03/2-A

Productomschrijving

EAN: 4014712235922 - manufacturer-number: DAFDD1C16/0,03/2-A - Earth leakage circuit breaker with Number of poles 2, Rated voltage 240V, Rated current 16A, Rated fault current 0,03A, Leakage current type A, Current limiting class 3, Rated short-circuit breaking capacity acc. EN 61009 10kA, Frequency 50Hz, Release characteristic C, Over voltage category 3, Pollution degree 2, Width in number of modular spacings 3, Built-in depth 70mm, Additional equipment attached at delivery Fire protection switch, Rated switch current auxiliary device 16A, Rated voltage auxiliary device 240V, Control voltage type auxiliary equipment AC, Degree of protection (IP) IP20 - DAFDD 1 C16/0,03/2-A

Productspecificaties

Artikelnummer(s)
EAN
4014712235922
Brand
Doepke