webshop.nl
Categorieën
  Sluiten

Meer Siemens
Meer Siemens in Kabels

6XV1830-0ET10 - Telecommunication cable 2x8mm 6XV1830-0ET10

EAN: 4019169400343 - manufacturer-number: 6XV1830-0ET10 - Telecommunication cable 2x8mm Diameter conductor 8mm, Conductor category Class 2 = stranded, Number of cores 2, Core insulation material Other, Core identification Numbers, Screen over stranding element Braiding, Stranding Layers, Screen over stranding None, Protective sheath No, Material ou...
190,97

Webshops met dit product

Webshop
Bezorging
Prijs

Anderen bekeken ook

6XV1830-3DH15  - Data and communication cable 2x0,67mm 6XV1830-3DH15
6XV1830-3DH15 - Data and communication cable 2x0,67mm 6XV1830-3DH15
EAN: 4019169402095 - manufacturer-number: 6XV1830-3DH15 - Conductor surface=Bare, Diameter conductor=0,67 mm, Nominal cross section conductor=0 mm², Conductor category=Class 5 = flexible, Number of cores=2, Number of stranding elements=1, Stranding element=Pairs, Material core insulation=Other, Specification core insulation=Polyethylene (PE), Core identification=Colour, Screen over stranding element=None, Stranding=Bundle, Screen over stranding=Foil + braiding, Suitable for underground installation=no, Protective sheath=None, Material outer sheath=Polyurethane (PUR), Specification material outer sheath=Other, Colour outer sheath=Other, Reaction-to-fire class according to EN 13501-6=None, Flame retardant=No, Low smoke (according to EN 61034-2)=no, Circuit integrity=None, Outer diameter approx.=8 mm, Permitted cable outer temperature during assembling/handling=-40..60 °C, Permitted cable outer temperature after assembling without vibration=-40..60 °C, Category=Other, NVP value=0 % - 6XV…
28,64
6XV1830-5FH10  - Data cable 2x1,05mm 6XV1830-5FH10
6XV1830-5FH10 - Data cable 2x1,05mm 6XV1830-5FH10
EAN: 4019169400442 - manufacturer-number: 6XV1830-5FH10 - Data cable 2x1,05mm Conductor surface Bare, Diameter conductor 1,05mm, Conductor category Class 1 = solid, Number of cores 2, Stranding element Pairs, Specification core insulation Polyethylene (PE), Core identification Colour, Screen over stranding element None, Screen over stranding Foil + braiding, Material outer sheath Polyvinyl chloride (PVC), Colour outer sheath Black, Flame retardant In accordance with EN 60332-3-24, Outer diameter approx. 8mm, Permitted cable outer temperature during assembling/handling -40 ... 80°C, Permitted cable outer temperature after assembling without vibration -40 ... 80°C - 6XV1830-5FH10
3,76
6XV1830-0JH10  - Data cable 2x0,65mm 6XV1830-0JH10
6XV1830-0JH10 - Data cable 2x0,65mm 6XV1830-0JH10
EAN: 4019169400381 - manufacturer-number: 6XV1830-0JH10 - Data cable 2x0,65mm Conductor surface Bare, Diameter conductor 0,65mm, Conductor category Class 1 = solid, Number of cores 2, Stranding element Pairs, Specification core insulation Polyethylene (PE), Core identification Colour, Screen over stranding element None, Screen over stranding Foil + braiding, Material outer sheath Polyurethane (PUR), Flame retardant In accordance with EN 60332-1-2, Outer diameter approx. 8mm, Permitted cable outer temperature during assembling/handling -40 ... 60°C, Permitted cable outer temperature after assembling without vibration -40 ... 60°C - 6XV1830-0JH10
4,69
J-2Y(ST)Y 2x2x0,6  - Telecommunication cable 4x0,6mm J-2Y(ST)Y 2x2x0,6
J-2Y(ST)Y 2x2x0,6 - Telecommunication cable 4x0,6mm J-2Y(ST)Y 2x2x0,6
manufacturer-number: J-2Y(ST)Y2x2x0,6 - Telecommunication cable 4x0,6mm Diameter conductor 0,6mm, Conductor category Class 1 = solid, Number of cores 4, Number of stranding elements 2, Stranding element Quad, Specification core insulation Polyethylene (PE), Core identification Colour + rings, Screen over stranding element None, Stranding Bundles and layers, Screen over stranding Foil, Protective sheath No, Material outer sheath Polyvinyl chloride (PVC), Colour outer sheath Grey, Flame retardant No, Circuit integrity No, Outer diameter approx. 7,4mm, Permitted cable outer temperature during assembling/handling -5 ... 70°C, Permitted cable outer temperature after assembling without vibration -30 ... 70°C - J-2Y(ST)Y 2x2x0,6
0,73
JY(ST)Y 3x2x0,6Eca  (100 Meter) - Telecommunication cable 6x0,6mm JY(ST)Y 3x2x0,6Eca ring 100m
JY(ST)Y 3x2x0,6Eca (100 Meter) - Telecommunication cable 6x0,6mm JY(ST)Y 3x2x0,6Eca ring 100m
manufacturer-number: JY(ST)Y3x2x0,6Eca - Telecommunication cable 6x0,6mm Diameter conductor 0,6mm, Conductor category Class 1 = solid, Number of cores 6, Number of stranding elements 3, Stranding element Pairs, Core insulation material Polyvinyl chloride (PVC), Core identification Colour, Screen over stranding element None, Stranding Layers, Screen over stranding Foil, Protective sheath No, Material outer sheath Polyvinyl chloride (PVC), Colour outer sheath Grey, Reaction-to-fire class according to EN 13501-6 Eca, Flame retardant No, Circuit integrity No, Outer diameter approx. 6mm, Permitted cable outer temperature during assembling/handling -5 ... 50°C, Permitted cable outer temperature after assembling without vibration -30 ... 70°C - JY(ST)Y 3x2x0,6Eca
73,77
JY(ST)Y 2x2x0,6Eca  (100 Meter) - Telecommunication cable 4x0,6mm JY(ST)Y 2x2x0,6Eca ring 100m
JY(ST)Y 2x2x0,6Eca (100 Meter) - Telecommunication cable 4x0,6mm JY(ST)Y 2x2x0,6Eca ring 100m
manufacturer-number: JY(ST)Y2x2x0,6Eca - Telecommunication cable 4x0,6mm Diameter conductor 0,6mm, Conductor category Class 1 = solid, Number of cores 4, Number of stranding elements 2, Stranding element Pairs, Core insulation material Polyvinyl chloride (PVC), Core identification Colour, Screen over stranding element None, Stranding Layers, Screen over stranding Foil, Protective sheath No, Material outer sheath Polyvinyl chloride (PVC), Colour outer sheath Grey, Reaction-to-fire class according to EN 13501-6 Eca, Flame retardant No, Circuit integrity No, Outer diameter approx. 5mm, Permitted cable outer temperature during assembling/handling -5 ... 50°C, Permitted cable outer temperature after assembling without vibration -30 ... 70°C - JY(ST)Y 2x2x0,6Eca
29,04
JY(ST)Y 6x2x0,6Eca  (100 Meter) - Telecommunication cable 12x0,6mm JY(ST)Y 6x2x0,6Eca ring 100m
JY(ST)Y 6x2x0,6Eca (100 Meter) - Telecommunication cable 12x0,6mm JY(ST)Y 6x2x0,6Eca ring 100m
manufacturer-number: JY(ST)Y6x2x0,6Eca - Telecommunication cable 12x0,6mm Diameter conductor 0,6mm, Conductor category Class 1 = solid, Number of cores 12, Number of stranding elements 6, Stranding element Pairs, Core insulation material Polyvinyl chloride (PVC), Core identification Colour, Screen over stranding element None, Stranding Layers, Screen over stranding Foil, Protective sheath No, Material outer sheath Polyvinyl chloride (PVC), Colour outer sheath Grey, Reaction-to-fire class according to EN 13501-6 Eca, Flame retardant No, Circuit integrity No, Outer diameter approx. 7,6mm, Permitted cable outer temperature during assembling/handling -5 ... 50°C, Permitted cable outer temperature after assembling without vibration -30 ... 70°C - JY(ST)Y 6x2x0,6Eca
104,47
JY(ST)Y 6x2x0,6Eca  (250 Meter) - Telecommunication cable 12x0,6mm JY(ST)Y 6x2x0,6Eca ring 250m
JY(ST)Y 6x2x0,6Eca (250 Meter) - Telecommunication cable 12x0,6mm JY(ST)Y 6x2x0,6Eca ring 250m
manufacturer-number: JY(ST)Y6x2x0,6Eca - Telecommunication cable 12x0,6mm Diameter conductor 0,6mm, Conductor category Class 1 = solid, Number of cores 12, Number of stranding elements 6, Stranding element Pairs, Core insulation material Polyvinyl chloride (PVC), Core identification Colour, Screen over stranding element None, Stranding Layers, Screen over stranding Foil, Protective sheath No, Material outer sheath Polyvinyl chloride (PVC), Colour outer sheath Grey, Reaction-to-fire class according to EN 13501-6 Eca, Flame retardant No, Circuit integrity No, Outer diameter approx. 7,6mm, Permitted cable outer temperature during assembling/handling -5 ... 50°C, Permitted cable outer temperature after assembling without vibration -30 ... 70°C - JY(ST)Y 6x2x0,6Eca
261,18
JY(ST)Y 6x2x0,8Eca  (100 Meter) - Telecommunication cable 12x0,8mm JY(ST)Y 6x2x0,8Eca ring 100m
JY(ST)Y 6x2x0,8Eca (100 Meter) - Telecommunication cable 12x0,8mm JY(ST)Y 6x2x0,8Eca ring 100m
manufacturer-number: JY(ST)Y6x2x0,8Eca - Telecommunication cable 12x0,8mm Diameter conductor 0,8mm, Conductor category Class 1 = solid, Number of cores 12, Number of stranding elements 6, Stranding element Pairs, Core insulation material Polyvinyl chloride (PVC), Core identification Colour, Screen over stranding element None, Stranding Layers, Screen over stranding Foil, Protective sheath No, Material outer sheath Polyvinyl chloride (PVC), Colour outer sheath Grey, Reaction-to-fire class according to EN 13501-6 Eca, Flame retardant No, Circuit integrity No, Outer diameter approx. 11mm, Permitted cable outer temperature during assembling/handling -5 ... 50°C, Permitted cable outer temperature after assembling without vibration -30 ... 70°C - JY(ST)Y 6x2x0,8Eca
162,05
JY(ST)Y 10x2x0,8Eca  (100 Meter) - Telecommunication cable 20x0,8mm JY(ST)Y 10x2x0,8Eca ring 100m
JY(ST)Y 10x2x0,8Eca (100 Meter) - Telecommunication cable 20x0,8mm JY(ST)Y 10x2x0,8Eca ring 100m
manufacturer-number: JY(ST)Y10x2x0,8Eca - Telecommunication cable 20x0,8mm Diameter conductor 0,8mm, Conductor category Class 1 = solid, Number of cores 20, Number of stranding elements 10, Stranding element Pairs, Core insulation material Polyvinyl chloride (PVC), Core identification Colour, Screen over stranding element None, Stranding Layers, Screen over stranding Foil, Protective sheath No, Material outer sheath Polyvinyl chloride (PVC), Colour outer sheath Grey, Reaction-to-fire class according to EN 13501-6 Eca, Flame retardant No, Circuit integrity No, Outer diameter approx. 14mm, Permitted cable outer temperature during assembling/handling -5 ... 50°C, Permitted cable outer temperature after assembling without vibration -30 ... 70°C - JY(ST)Y 10x2x0,8Eca
252,58

Klanten-reviews van 6XV1830-0ET10 - Telecommunication cable 2x8mm 6XV1830-0ET10

Er zijn nog geen beoordelingen voor dit productBen jij de eerste die een review plaatst?

Meer over 6XV1830-0ET10 - Telecommunication cable 2x8mm 6XV1830-0ET10

Productomschrijving

EAN: 4019169400343 - manufacturer-number: 6XV1830-0ET10 - Telecommunication cable 2x8mm Diameter conductor 8mm, Conductor category Class 2 = stranded, Number of cores 2, Core insulation material Other, Core identification Numbers, Screen over stranding element Braiding, Stranding Layers, Screen over stranding None, Protective sheath No, Material outer sheath Polyvinyl chloride (PVC), Flame retardant No, Circuit integrity No, Outer diameter approx. 8mm, Permitted cable outer temperature during assembling/handling -40 ... 60°C, Permitted cable outer temperature after assembling without vibration -40 ... 60°C - 6XV1830-0ET10

Productspecificaties

Artikelnummer(s)
EAN
4019169400343
Brand
Siemens
Kenmerken
Kleur van het product
Meerkleurig
Verpakking
Gewicht
7,78 kg
Aantal per verpakking
1 stuk(s)
Webshop.nl maakt gebruik van cookies. Ga je verder op onze website, ga dan akkoord met het plaatsen van cookies en de verwerking van deze data door ons en vermelde partners.