ADA516D - Earth leakage circuit breaker B16/0,03A ADA516D

EAN: 3250611067764 - manufacturer-number: ADA516D - Earth leakage circuit breaker B16/0,03A Number of poles (total) 2, Number of protected poles 1, Rated voltage 240V, Rated insulation voltage Ui 500V, Rated impulse withstand voltage Uimp 4kV, Rated current 16A, Rated fault current 0,03A, Leakage current type A, Current limiting class 3, Rated shor...
51,-

Webshops met dit product

Webshop
Bezorging
Prijs

Anderen bekeken ook

5SU1324-6FA16  - Earth leakage circuit breaker B16/0,03A 5SU1324-6FA16
5SU1324-6FA16 - Earth leakage circuit breaker B16/0,03A 5SU1324-6FA16
EAN: 4001869305837 - manufacturer-number: 5SU1324-6FA16 - Earth leakage circuit breaker B16/0,03A Number of poles (total) 2, Number of protected poles 2, Rated voltage 230V, Rated insulation voltage Ui 264V, Rated impulse withstand voltage Uimp 4kV, Rated current 16A, Rated fault current 0,03A, Leakage current type A, Current limiting class 3, Rated short-circuit breaking capacity acc. EN 61009 10kA, Rated short-circuit breaking capacity IEC 60947-2 20kA, Rated short-circuit breaking capacity Icn acc. EN 61009-1 10kA, Disconnection characteristic Undelayed, Surge current capacity 1kA, Voltage type AC, Release characteristic B, Concurrently switching N-neutral, With interlocking device, Over voltage category 3, Pollution degree 2, Ambient temperature during operating -25 ... 55°C, Width in number of modular spacings 3, Built-in depth 70mm, Suitable for flush-mounted installation, Anti-nuisance tripping version, Degree of protection (IP) IP20, Connectable conductor cross section solid-co…
117,74
ADX416D  - Earth leakage circuit breaker B16/0,03A ADX416D
ADX416D - Earth leakage circuit breaker B16/0,03A ADX416D
EAN: 3250611016960 - manufacturer-number: ADX416D - Earth leakage circuit breaker B16/0,03A Number of poles (total) 4, Number of protected poles 4, Rated voltage 400V, Rated insulation voltage Ui 500V, Rated impulse withstand voltage Uimp 4kV, Rated current 16A, Rated fault current 0,03A, Leakage current type A, Current limiting class 3, Rated short-circuit breaking capacity IEC 60947-2 10kA, Rated short-circuit breaking capacity Icn acc. EN 61009-1 10kA, Surge current capacity 3kA, Voltage type AC, Frequency 50 Hz, Release characteristic B, Over voltage category 3, Pollution degree 2, Width in number of modular spacings 4, Built-in depth 70mm, Suitable for flush-mounted installation, Degree of protection (IP) IP20 - ADX416D
208,12
DRCBO3B16/0,03/1NAKV  - Earth leakage circuit breaker B16/0,03A DRCBO3B16/0,03/1NAKV
DRCBO3B16/0,03/1NAKV - Earth leakage circuit breaker B16/0,03A DRCBO3B16/0,03/1NAKV
EAN: 4014712220928 - manufacturer-number: DRCBO3B16/0,03/1NAKV - Earth leakage circuit breaker B16/0,03A Number of poles (total) 2, Number of protected poles 1, Rated voltage 230V, Rated insulation voltage Ui 440V, Rated impulse withstand voltage Uimp 4kV, Rated current 16A, Rated fault current 0,03A, Leakage current type A, Current limiting class 3, Rated short-circuit breaking capacity acc. EN 61009 10kA, Rated short-circuit breaking capacity IEC 60947-2 10kA, Rated short-circuit breaking capacity Icn acc. EN 61009-1 10kA, Disconnection characteristic Short-time delayed, Surge current capacity 3kA, Voltage type AC, Frequency 50 Hz, Release characteristic B, Over voltage category 3, Pollution degree 2, Ambient temperature during operating -25 ... 40°C, Width in number of modular spacings 2, Built-in depth 68mm, Degree of protection (IP) IP20, Connectable conductor cross section solid-core 1 ... 25mm², Connectable conductor cross section multi-wired 1 ... 25mm² - DRCBO3B16/0,03/1NAKV
92,36
GW95326  - Earth leakage circuit breaker B10/0,03A GW95326
GW95326 - Earth leakage circuit breaker B10/0,03A GW95326
EAN: 8011564299221 - manufacturer-number: GW95326 - Earth leakage circuit breaker B10/0,03A Number of poles (total) 2, Number of protected poles 2, Rated voltage 230V, Rated insulation voltage Ui 500V, Rated impulse withstand voltage Uimp 4kV, Rated current 10A, Rated fault current 0,03A, Leakage current type A, Current limiting class 3, Rated short-circuit breaking capacity according to EN 61009 10kA, Rated short-circuit breaking capacity according to IEC 60947-2 15kA, Rated short-circuit breaking capacity Icn according to EN 61009-1 10kA, Disconnection characteristic Undelayed, Surge current capacity 0,25kA, Voltage type AC, Frequency 50 Hz, Release characteristic B, Over voltage category 3, Pollution degree 2, Ambient temperature during operating -25 ... 40°C, Width in number of modular spacings 2, Built-in depth 72mm, Degree of protection (IP) IP20, Connectable conductor cross section solid-core 35 ... 35mm², Connectable conductor cross section multi-wired 35 ... 35mm² - GW95326
47,73
DS201A-B16/0,03  - Earth leakage circuit breaker B16/0,03A DS201A-B16/0,03
DS201A-B16/0,03 - Earth leakage circuit breaker B16/0,03A DS201A-B16/0,03
EAN: 8012542058519 - manufacturer-number: DS201A-B16/0,03 - Earth leakage circuit breaker B16/0,03A Number of poles (total) 2, Number of protected poles 1, Rated voltage 230V, Rated insulation voltage Ui 500V, Rated current 16A, Rated fault current 0,03A, Leakage current type A, Current limiting class 3, Rated short-circuit breaking capacity IEC 60947-2 10kA, Rated short-circuit breaking capacity Icn acc. EN 61009-1 6kA, Frequency 50/60 Hz, Release characteristic B, Concurrently switching N-neutral, Over voltage category 3, Pollution degree 2, Ambient temperature during operating -25 ... 55°C, Width in number of modular spacings 2, Built-in depth 69mm, Degree of protection (IP) IP20 - DS201A-B16/0,03
39,54
ADX420D  - Earth leakage circuit breaker B16/0,03A ADX420D
ADX420D - Earth leakage circuit breaker B16/0,03A ADX420D
EAN: 3250611016977 - manufacturer-number: ADX420D - Earth leakage circuit breaker B16/0,03A Number of poles (total) 4, Number of protected poles 4, Rated voltage 400V, Rated insulation voltage Ui 500V, Rated impulse withstand voltage Uimp 4kV, Rated current 20A, Rated fault current 0,03A, Leakage current type A, Current limiting class 3, Rated short-circuit breaking capacity Icn acc. EN 61009-1 10kA, Surge current capacity 3kA, Voltage type AC, Frequency 50 Hz, Release characteristic B, Over voltage category 3, Pollution degree 2, Width in number of modular spacings 4, Built-in depth 70mm, Suitable for flush-mounted installation, Degree of protection (IP) IP20 - ADX420D
216,65
5SU1324-7FA06  - Earth leakage circuit breaker C6/0,03A 5SU1324-7FA06
5SU1324-7FA06 - Earth leakage circuit breaker C6/0,03A 5SU1324-7FA06
EAN: 4001869305882 - manufacturer-number: 5SU1324-7FA06 - Earth leakage circuit breaker C6/0,03A Number of poles (total) 2, Number of protected poles 2, Rated voltage 230V, Rated insulation voltage Ui 264V, Rated impulse withstand voltage Uimp 4kV, Rated current 6A, Rated fault current 0,03A, Leakage current type A, Current limiting class 3, Rated short-circuit breaking capacity acc. EN 61009 10kA, Rated short-circuit breaking capacity IEC 60947-2 35kA, Rated short-circuit breaking capacity Icn acc. EN 61009-1 10kA, Disconnection characteristic Undelayed, Surge current capacity 1kA, Voltage type AC, Frequency 50 Hz, Release characteristic C, Concurrently switching N-neutral, With interlocking device, Over voltage category 3, Pollution degree 2, Ambient temperature during operating -25 ... 55°C, Width in number of modular spacings 3, Built-in depth 70mm, Suitable for flush-mounted installation, Anti-nuisance tripping version, Degree of protection (IP) IP20, Connectable conductor cross s…
126,20
5SU1324-7FA10  - Earth leakage circuit breaker C10/0,03A 5SU1324-7FA10
5SU1324-7FA10 - Earth leakage circuit breaker C10/0,03A 5SU1324-7FA10
EAN: 4001869305899 - manufacturer-number: 5SU1324-7FA10 - Earth leakage circuit breaker C10/0,03A Number of poles (total) 2, Number of protected poles 2, Rated voltage 230V, Rated insulation voltage Ui 264V, Rated impulse withstand voltage Uimp 4kV, Rated current 10A, Rated fault current 0,03A, Leakage current type A, Current limiting class 3, Rated short-circuit breaking capacity acc. EN 61009 10kA, Rated short-circuit breaking capacity IEC 60947-2 20kA, Rated short-circuit breaking capacity Icn acc. EN 61009-1 10kA, Disconnection characteristic Undelayed, Surge current capacity 1kA, Voltage type AC, Frequency 50 Hz, Release characteristic C, Concurrently switching N-neutral, With interlocking device, Over voltage category 3, Pollution degree 2, Ambient temperature during operating -25 ... 55°C, Width in number of modular spacings 3, Built-in depth 70mm, Suitable for flush-mounted installation, Anti-nuisance tripping version, Degree of protection (IP) IP20, Connectable conductor cross…
126,20
ADA520D  - Earth leakage circuit breaker B20/0,03A ADA520D
ADA520D - Earth leakage circuit breaker B20/0,03A ADA520D
EAN: 3250611067771 - manufacturer-number: ADA520D - Earth leakage circuit breaker B20/0,03A Number of poles (total) 2, Number of protected poles 1, Rated voltage 240V, Rated insulation voltage Ui 500V, Rated impulse withstand voltage Uimp 4kV, Rated current 20A, Rated fault current 0,03A, Leakage current type A, Current limiting class 3, Rated short-circuit breaking capacity IEC 60947-2 10kA, Rated short-circuit breaking capacity Icn acc. EN 61009-1 10kA, Voltage type AC, Frequency 50 Hz, Release characteristic B, Concurrently switching N-neutral, Over voltage category 3, Pollution degree 2, Width in number of modular spacings 2, Built-in depth 68mm, Suitable for flush-mounted installation, Degree of protection (IP) IP20 - ADA520D
74,16
ADA532D  - Earth leakage circuit breaker B32/0,03A ADA532D
ADA532D - Earth leakage circuit breaker B32/0,03A ADA532D
EAN: 3250611067795 - manufacturer-number: ADA532D - Earth leakage circuit breaker B32/0,03A Number of poles (total) 2, Number of protected poles 1, Rated voltage 240V, Rated insulation voltage Ui 500V, Rated impulse withstand voltage Uimp 4kV, Rated current 32A, Rated fault current 0,03A, Leakage current type A, Current limiting class 3, Rated short-circuit breaking capacity IEC 60947-2 10kA, Rated short-circuit breaking capacity Icn acc. EN 61009-1 10kA, Voltage type AC, Frequency 50 Hz, Release characteristic B, Concurrently switching N-neutral, Over voltage category 3, Pollution degree 2, Width in number of modular spacings 2, Built-in depth 68mm, Suitable for flush-mounted installation, Degree of protection (IP) IP20 - ADA532D
76,90

Klanten-reviews van ADA516D - Earth leakage circuit breaker B16/0,03A ADA516D

Er zijn nog geen beoordelingen voor dit productBen jij de eerste die een review plaatst?

Meer over ADA516D - Earth leakage circuit breaker B16/0,03A ADA516D

Productomschrijving

EAN: 3250611067764 - manufacturer-number: ADA516D - Earth leakage circuit breaker B16/0,03A Number of poles (total) 2, Number of protected poles 1, Rated voltage 240V, Rated insulation voltage Ui 500V, Rated impulse withstand voltage Uimp 4kV, Rated current 16A, Rated fault current 0,03A, Leakage current type A, Current limiting class 3, Rated short-circuit breaking capacity IEC 60947-2 10kA, Rated short-circuit breaking capacity Icn acc. EN 61009-1 10kA, Voltage type AC, Frequency 50 Hz, Release characteristic B, Concurrently switching N-neutral, Over voltage category 3, Pollution degree 2, Width in number of modular spacings 2, Built-in depth 68mm, Suitable for flush-mounted installation, Degree of protection (IP) IP20 - ADA516D

Productspecificaties

Artikelnummer(s)
EAN
3250611067764
Brand
Hager
Energie
AC-ingangsspanning
240 V
Technische details
Duurzaamheidscertificaten
RoHS
Inhoud van de verpakking
Aantal
1